Engineered for seamless DIN-rail integration, reliable thermal-magnetic tripping, and optimal overload protection across Saudi commercial and residential power distribution boards.
As the Kingdom of Saudi Arabia advances rapidly under the blueprint of Saudi Vision 2030, the city of Riyadh is witnessing an unprecedented expansion in urban infrastructure, mega-commercial complexes, smart data hubs, and industrial zones under the governance of MODON (Saudi Authority for Industrial Cities and Technology Zones). This massive infrastructure growth demands an uncompromising standard for low-voltage power distribution networks. Central to this electrical infrastructure is the protection of final sub-circuits against short-circuits and current overloads. The OFL7 Series Miniature Circuit Breaker (MCB) engineered by Wenzhou OFA Electrical Technology Co., Ltd. represents a benchmark in technical precision, thermal resilience, and electrical endurance designed specifically to address the demanding operating conditions of the Arabian Peninsula.
Electrical procurement in Riyadh demands strict compliance with Saudi Standards, Metrology and Quality Organization (SASO) directives and SABER platform registration. Low-voltage protective switchgear installed within the Central Province must adhere strictly to IEC/EN 60898-1 and IEC/EN 60947-2 standards, while matching the specific 220V/380V and dual-voltage transition standards enforced by the Saudi Electricity Company (SEC).
The OFL7 Series MCB has been rigorously type-tested to ensure seamless integration with local distribution board configurations, including surface-mounted metal enclosures (DBs), main distribution boards (MDBs), and sub-main distribution boards (SMDBs). Key environmental and physical stress factors considered during the design phase include:
The OFL7 Series spans single-pole (1P), two-pole (2P), three-pole (3P), and four-pole (4P) configurations, covering rated operating currents from 1A up to 63A. The unit is optimized for quick installation onto standard 35mm DIN rails, featuring dual-stable DIN-rail clips for hassle-free mounting and maintenance.
| Technical Parameter | OFL7 Standard Specification | Riyadh Field Application Relevance |
|---|---|---|
| Rated Current ($I_n$) | 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | Covers all domestic, commercial, and light industrial sub-circuit protection needs. |
| Rated Voltage ($U_e$) | 230/400V AC (1P), 400V AC (2P, 3P, 4P), 50/60Hz | Fully compliant with KSA SEC grid frequency (60Hz) and nominal operating voltages. |
| Rated Short-Circuit Capacity ($I_{cn}$) | 6,000A / 10,000A (IEC 60898-1) | Ensures rapid arc extinction and breaker survival during heavy dead-short faults. |
| Tripping Curves | B Curve (3-5 $I_n$), C Curve (5-10 $I_n$), D Curve (10-14 $I_n$) | B curve for resistive loads; C curve for general building services; D curve for high-inductive motors/pumps. |
| Insulation Voltage ($U_i$) | 500V AC | Provides complete galvanically isolated protection during maintenance lock-out procedures. |
| Housing Material | Polyamide PA66, Flame Retardant (UL94-V0) | Self-extinguishing material prevents electrical fires in extreme overheat scenarios. |
| Terminal Connection Size | 1 to 25 $\text{mm}^2$ flexible/rigid cable | Accommodates standard copper conductor sizing mandated by KSA wiring regulations. |
The global low-voltage circuit breaker market is shifting rapidly toward intelligent, eco-friendly, and modular protection devices. Modern building management systems (BMS) require high data visibility, compact footprints, and hybrid protection combining Miniature Circuit Breakers with Residual Current Protection with Overcurrent (RCBO) and Arc Fault Detection Devices (AFDD).
Wenzhou OFA Electrical Technology Co., Ltd. is positioned at the forefront of this evolution. Our ongoing R&D roadmap emphasizes smart IoT-enabled MCBs capable of real-time temperature tracking, current leakage measurement, and remote automated tripping/resetting via wireless protocols. As Riyadh scales up solar power adoption—driven by the National Renewable Energy Program (NREP)—OFA’s specialized DC circuit breaker series (such as DCOF1) and combined protection units work in tandem with OFL7 AC distribution boards to create hybrid microgrid infrastructure.
Deploying proven OFL7 switchgear configurations across diverse commercial, industrial, and infrastructure applications in Saudi Arabia.
Ideal for landmark developments such as King Abdullah Financial District (KAFD). OFL7 MCBs offer high packing density in floor distribution boards, ensuring fast selectivity, branch circuit isolation, and zero disruption to critical IT loads.
Supplying robust 1P and 2P OFL7 breakers for distribution enclosures in Riyadh residential expansion zones. Complete protection against household appliance overloads, HVAC surge currents, and short-circuits.
Heavy-duty 3P and 4P OFL7 variants rated up to 10kA breaking capacity for heavy motor drives, automated conveyers, and processing machinery in Riyadh 1st, 2nd, and 3rd Industrial Cities.
Founded in 2013, Wenzhou OFA Electrical Technology Co., Ltd. is rooted in Yueqing, Wenzhou—the renowned Capital of Electrical Appliances in China. We are a specialized, technology-driven enterprise dedicated to the research, development, lean manufacturing, and global export of high-performance distribution switchgear, circuit protection components, and smart control equipment.
Operating under our independent proprietary brand "OFA", our product matrix spans Molded Case Circuit Breakers (MCCB), Miniature Circuit Breakers (MCB), Air Circuit Breakers (ACB), Residual Current Circuit Breakers (RCCB), RCBOs, and Isolator Switches (IS). We adhere strictly to ISO9001 quality management system standards and maintain a continuous 100% full-inspection SOP across automated assembly lines.
Explore our complete collection of OEM/ODM circuit breakers, residual current devices, solar DC molded case breakers, and isolators ready for export to Saudi Arabia.
From technical parameter matching to SABER certification and rapid sea/air shipping, we streamline low-voltage equipment sourcing for Saudi partners.
Submit your single-line diagrams (SLD) or target technical parameters (breaking capacity, tripping curve, pole count). OFA engineers match the optimum OFL7 configuration.
Custom prototype production with client laser branding, terminal tweaks, and full laboratory validation under elevated temperature conditions matching KSA summers.
Digitalized automated assembly lines ensure strict in-process quality checkpoints, laser marking, calibration, and 100% full-load trip verification before packaging.
Issuance of SASO compliance documentation, CoC (Certificate of Conformity), and robust export packaging designed for ocean freight to Dammam/Jeddah or air shipment to Riyadh (RUH).
Discover why leading electrical engineers and project managers choose OFA switchgear across international markets.
"Deploying OFA's miniature circuit breakers and energy monitoring equipment across our residential development projects yielded exceptional operational stability. The thermal performance under heavy AC loads in peak summer met all our strict criteria."
"As a system integrator operating in demanding climates, OFA’s product range simplified our panel building process. Their OFL7 series offers reliable C-curve characteristics with consistent thermal calibration."
"OFA's remote technical assistance and complete SASO/IEC documentation support made our export and site commissioning phase in the Middle East smooth and fully compliant with local electrical authority requirements."
Detailed technical answers for Saudi electrical contractors, procurement specialists, and panel builders.
A: The OFL7 Series miniature circuit breakers are fully compliant with international standard IEC/EN 60898-1 and carry CE certification. For Saudi Arabian imports, OFA provides full documentation support to facilitate SABER platform registration and issue the Certificate of Conformity (CoC) required by SASO customs regulations.
A: In Riyadh, panel interior temperatures often exceed 50°C to 55°C. OFA provides specific thermal compensation curves and derating factor tables for the OFL7 Series. By adjusting the bimetal thermal element or selecting appropriately recalibrated current ratings ($I_n$), we prevent false tripping while guaranteeing 100% magnetic protection during short-circuit events.
A: The OFL7 Series is available in B, C, and D tripping curves. B Curve (3-5 $I_n$) is recommended for electronic circuits and resistive heating; C Curve (5-10 $I_n$) serves as the standard choice for general commercial lighting, power outlets, and building services in Riyadh; D Curve (10-14 $I_n$) is specifically used for high inductive surge loads like heavy HVAC compressors, water pumps, and industrial motors.
A: An RCBO (such as the OFR1 or OFDPN series) combines residual current protection (earth leakage) and overcurrent/short-circuit protection into a single compact device. This reduces panel space by 50%, minimizes internal wiring work, eliminates potential terminal hot-spots, and provides independent circuit fault isolation—ensuring that an earth fault on one branch does not trip unrelated healthy circuits.
A: Yes. OFA specializes in flexible OEM/ODM manufacturing. We support custom front-plate laser printing (brand logo, part numbers, barcoding), customized color-coded toggle switches, customized box packaging, and language-specific instruction sheets (Arabic/English) tailored to Saudi market distributor requirements.
A: Standard product configurations maintain buffer component stocks, enabling quick production turnaround in 15-25 days depending on volume. Logistics options include sea freight to King Abdulaziz Port in Dammam or Jeddah Islamic Port, with inland transit to Riyadh, as well as expedited air freight directly to King Khalid International Airport (RUH) for urgent site requirements.
Upgrade your Riyadh electrical distribution projects with high-reliability, SASO-compliant OFL7 Series circuit breakers and low-voltage protection components from Wenzhou OFA Electrical Technology Co., Ltd.
Send Inquiry Now