High-Quality OFA-M1 Series 250 A Molded Case Circuit Breaker Factories, Suppliers

— The Main Barrier for High-Current Distribution Circuits
As the capacity of low-voltage distribution systems increases, the 250 A current rating becomes a critical node for main feeders and the supply of large equipment. The OFA-M1 series OFAM1-250/3300 molded case circuit breaker, with a frame rated current of 250 A, a rated ultimate short-circuit breaking capacity of 35 kA, a service short-circuit breaking capacity of 22 kA, a rated insulation voltage of 690 V and an impulse withstand voltage of 6 kV, uses a robust electrical and mechanical structure to withstand continuous heavy loads and potential severe short circuits. The product is manufactured in strict accordance with the GB/T 14048.2 standard and is an indispensable protective component in the distribution systems of industrial plants, commercial complexes and critical infrastructure.

Product Description

Related Products

OFA-M1 Series 400 A Molded Case Circuit Breaker
Industrial Grade

OFA-M1 Series 400 A Molded Case Circuit Breaker

OFA-M1 Series 630 A Molded Case Circuit Breaker
High Capacity

OFA-M1 Series 630 A Molded Case Circuit Breaker

OFA-M1 Series 125 A Molded Case Circuit Breaker
Standard Range

OFA-M1 Series 125 A Molded Case Circuit Breaker

OFA-M1 Series 63 A Molded Case Circuit Breaker
Compact Model

OFA-M1 Series 63 A Molded Case Circuit Breaker

Frequently Asked Questions

What is a Molded Case Circuit Breaker (MCCB)?

A Molded Case Circuit Breaker (MCCB) is a type of electrical protection device used to safeguard electrical circuits from excessive current, which can cause overloads or short circuits. MCCBs feature a molded plastic housing that isolates internal components and provides adjustable trip settings for higher current capacities compared to standard miniature circuit breakers.

How do I choose the correct ampere rating for OFA-M1 Series MCCBs?

Selection depends on the total continuous operating current of your electrical load and system requirements. The OFA-M1 series offers options ranging from 63A to 630A. Ensure the rated current matches the maximum continuous load while allowing safe operational margins according to local electrical safety standards.

What is the main difference between MCCB and MCB?

Main differences include current capacity, trip settings, and application scale. MCBs (Miniature Circuit Breakers) are generally used for low-current applications (up to 100A) with fixed trip characteristics, whereas MCCBs handle higher current loads (up to 2500A) and often feature adjustable trip thresholds suitable for industrial setups.

What protection functions are integrated into the OFA-M1 Series?

The OFA-M1 series incorporates dual protection mechanisms: thermal protection against prolonged overloads and electromagnetic protection against sudden short circuits, ensuring maximum protection for power distribution systems and connected machinery.

Can OFA-M1 Series MCCBs be used in industrial environments?

Yes, the OFA-M1 Series circuit breakers are specifically built with durable molded housings and robust internal contacts, making them highly suitable for heavy-duty commercial and industrial power distribution environments.